UA Connection Problems to Opto22 Groov after TOP Server upgrade
I am using the Opto22 Groov22 OPC Client, with a OPC UA connection to TOP Server. This was working, but after upgrading my TOP Server 5 version I am receiving connection problems. How can I get Groov22 to communicate with TOP Server again?
This problem is likely a result of the OPC UA configuration changes that are possible depending on what version is being upgraded from and what version is being upgraded to. Please verify the following settings:
- Open the TOP Server OPC UA Configuration utility from the Software Toolbox Folder in the start menu, and make note of the Endpoint URLs.
- Verify that the security for the endpoint that will be used is set to "None". If not, double click the end point and change it.
- Right click on the TOP Server Icon in the System tray and "Reinitialize" the server - this step is required to commit the endpoint URL Changes
- In the Groov22 client add a new OPC UA Server, give it a user friendly name, and use the Endpoint URL that was recorded in step 1.
The Groov22 error messages will generally mention incorrect security when connecting to the UA Server - if a different error is seen, or you are not sure whether the error is related to the security settings, please open a support ticket for assistance.